Industrial glycol air cooler for chiller room 10°C

The GS series industrial glycol air coolers is mainly used for cooling equipment in cold storage with glycol coolant. The low temperature glycol aqueous solution in the heat exchanger tube of the air cooler to absorb the external heat so as to reduce the storage temperature. The GS series air cooler can be used in cold storage at about 10°C, 0°C and -18°C respectively


  • Item NO.:

    GS166E/340M
  • Payment:

    T/T
  • Product Origin:

    China
  • Color:

    white
  • Shipping Port:

    Guangzhou

Product Description 

  • Casing

    Adopt high-quality steel plate with powder coating RAL9003, hinged structure is adopted for both side plateds and external drip tray, which is convenient and quick to operate.

  • Fans

    External rotor motor with high wind pressure, working ambient temperature -40~60°C.

    High air duct design with Integral stretching , good ventilation effect, further airthrow , lower noise, Fans individually connected to junction box ; Fan blade Φ400,Φ500,Φ630, standard 4-pole motor.

  • Heat Exchanger Coil

    Copper tubing Φ15, spacing 50X50

    Corrugated aluminium fins, fin spacing 4.2mm and 6.4mm and 9.0mm

  • Electric Defrosting

    The stainless electirc heating pipe installed in the middle of coil and inner water plated , permits quick and efficient defrost of the coil. Independent electric heating pipes junction box.

Specification

Model fin spacing 4.2mm for 10°C, Fan 400mm, 500mm, 630mm

Industrial glycol air cooler for 10°C.jpg

Industrial glycol air cooler .jpg





Leave A Message
If you are interested in our products and want to know more details,please leave a message here,we will reply you as soon as we can.
Related Products
glycol air cooler for -18°C
Low maintenance cost industrial glycol air cooler for -18°C
The GS series industrial glycol air coolers is mainly used for cooling equipment in cold storage with glycol coolant. The low temperature glycol aqueous solution in the heat exchanger tube of the air cooler to absorb the external heat so as to reduce the storage temperature. The GS series air cooler can be used in cold storage at about 10°C, 0°C and -18°C respectively.
View More
GS Series Air Cooler for Glycol Coolant
GS Series Air Cooler for Glycol Coolant
The GS series industrial glycol air coolers is mainly used for cooling equipment in cold storage with glycol coolant. The low temperature glycol aqueous solution in the heat exchanger tube of the air cooler to absorb the external heat so as to reduce the storage temperature. The GS series air cooler can be used in cold storage at about 10°C, 0°C and -18°C respectively
View More
CS ceilling unit evaporator
Air Cooler Unit For Low temperature Cold Room
CS one fan Upgraded Type Condenser Portable Air Cooler Evaporator For low temerature small Cold Room With Electrical Defrost.
View More
CS ceilling unit evaporator
Air Cooler Unit For Low temperature Cold Room
CS one fan Upgraded Type Condenser Portable Air Cooler Evaporator For low temerature small Cold Room With Electrical Defrost.
View More
Compressor and Condensing Unit
4EES-4Y Cold Storage Refrigeration Unit Bitzer Compressor
4EES-4Y Condensing Unit Refrigeration Compressor  Product description:   1.HCU series open-type air-cool condensing units have the following characteristics.Adopted semi-hermetic piston compressors with BITZER or FRASCOLD, It has good quality and high reliability. 2.The air-cooled condenser, compressor and various accessories are installed on an integral frame, which is compact in structure and convenient in operation and maintenance. 3.Adopted high duct condenser with external rotor fan , which has low noise and high efficiency. 4.The product series is complete, It has high,medium, low temperature and quick frozen working conditions design. It can meet the needs of refrigeration equipment at various temperatures. 5.It can meet the requirements of R22, R404A,R507A, R448A, R449A and other refrigerants.  Bitzer 4EES-4Y Condensing Unit Catalogue: Power Supply  380V 50Hz 3phase Apply Temp. -15 to -30 degree Compressor Model 4EES-4Y Compressor Max.I(A) 12.2 Fan Voltage (V) 380V 50Hz 3phase Fan Current (A) 1.04 Fan Power (W) 240X2 Suction Line (mm) 28 Liquid Line (mm) 12 Size length (mm) 1435 Size Width (mm) 850 Size Height (mm) 830
View More
compressor
BITZER 4PES-10(Y) ECOLINE reciprocating compressors
SEMI-HERMETIC For standard refrigerantsUniversal and environmentally friendly: ECOLINE reciprocating compressors offer high cooling capacity with minimal energy requirements and are optimised for HFC, HFO and low-GWP refrigerants. The optional VARISTEP mechanical capacity control offers high part-load efficiency in medium and low temperature application.
View More
refrigerated storage cold room
Vegetable fruit refrigerated storage cold room equipment
Whether you want any equipment for your vegetable or fruit refrigerated cold storage which over -5°C , we can provide whole cooling system products include condensing unit, air cooler, PU panel ,door and all accessories to you , and you just need to tell us : 1.The Length * Wide * High(m) of the cold room . 2. The room temperature you want ? Or what do you want to refrigerate ?  3. If there any other special requirement for voltage ?   
View More
Oil Separator
XMK-5201 1/2 ODF Oil Separator Refrigeration
XMK-5201 1/2 ODF Oil Separator RefrigerationWe oil separator has the great oil-separating capacity.The mixed gaseous refrigerant get into oil separator from compressor,carring oil to get through stainless steel mesh inlet.The oil particles collide and become heavier,impacting on the inwall and intermediate clapboard ultimately.The separated oil drop on the bottom of separator,when them accumulate to a certain amount,the oil will get back to compressor crankcase automatically through the pressure differential  ball float needle valve device.ModelConnector sizeXMK-52011/2 ODFXMK-52025/8 ODFXMK-52037/8 ODFXMK-52041-1/8 ODFXMK-52051-3/8 ODFXMK-62031-3/8 ODFXMK-62041-5/8 ODFXMK-62052-1/8 ODFProduction Introduction:The oil separator should be installed vertically and pre-charge the oil before installing oil separator,the oil should be same as the oil in the compressor crankcase.In the actual piping system,the excessive loads or vibration at the inlet and outlet should be prevented.Oil storage separator must be fixed in the mounting pin connections. Design features:1,Extra length multiayer filter mesh desgin will buffer the mixed gaseous refrigerant greatly.2,The installation of clapboard and spacer palte devide the space into three rooms,improving the efficiency of oil separating greatly.3,In practical application,the vibration of unit might affect ball float installation stability,so the clapboard and spacer plate could reduce the vibration og it.4,Reasonable stainless steel ball float installation desgin remove the crash of ball float and oil return pipe which reduced the noise.5,The installation of magner on the bottom absorb the remaining iron dust in the system helpfully. 
View More
Categories

click here to leave a message

Leave A Message
If you are interested in our products and want to know more details,please leave a message here,we will reply you as soon as we can.

Home

Products

about

contact