5 results found for "refrigeration parts"
  • Oil Separator
    Oil Separator
    XMK-5201 1/2 ODF Oil Separator Refrigeration
    XMK-5201 1/2 ODF Oil Separator RefrigerationWe oil separator has the great oil-separating capacity.The mixed gaseous refrigerant get into oil separator from compressor,carring oil to get through stainless steel mesh inlet.The oil particles collide and become heavier,impacting on the inwall and intermediate clapboard ultimately.The separated oil drop on the bottom of separator,when them accumulate to a certain amount,the oil will get back to compressor crankcase automatically through the pressure differential  ball float needle valve device.ModelConnector sizeXMK-52011/2 ODFXMK-52025/8 ODFXMK-52037/8 ODFXMK-52041-1/8 ODFXMK-52051-3/8 ODFXMK-62031-3/8 ODFXMK-62041-5/8 ODFXMK-62052-1/8 ODFProduction Introduction:The oil separator should be installed vertically and pre-charge the oil before installing oil separator,the oil should be same as the oil in the compressor crankcase.In the actual piping system,the excessive loads or vibration at the inlet and outlet should be prevented.Oil storage separator must be fixed in the mounting pin connections. Design features:1,Extra length multiayer filter mesh desgin will buffer the mixed gaseous refrigerant greatly.2,The installation of clapboard and spacer palte devide the space into three rooms,improving the efficiency of oil separating greatly.3,In practical application,the vibration of unit might affect ball float installation stability,so the clapboard and spacer plate could reduce the vibration og it.4,Reasonable stainless steel ball float installation desgin remove the crash of ball float and oil return pipe which reduced the noise.5,The installation of magner on the bottom absorb the remaining iron dust in the system helpfully. 
  • Oil Separator Air Condition
    Oil Separator Air Condition
    5/8 ODF Oil Separator Air Condition And Refrigeration Spare Parts
    XMK-5202 5/8 ODF Oil Separator Refrigeration For Condensing UnitWe oil separator has the great oil-separating capacity.The mixed gaseous refrigerant get into oil separator from compressor,carring oil to get through stainless steel mesh inlet.The oil particles collide and become heavier,impacting on the inwall and intermediate clapboard ultimately.The separated oil drop on the bottom of separator,when them accumulate to a certain amount,the oil will get back to compressor crankcase automatically through the pressure differential  ball float needle valve device.ModelConnector sizeXMK-52011/2 ODFXMK-52025/8 ODFXMK-52037/8 ODFXMK-52041-1/8 ODFXMK-52051-3/8 ODFXMK-62031-3/8 ODFXMK-62041-5/8 ODFXMK-62052-1/8 ODFProduction Introduction:The oil separator should be installed vertically and pre-charge the oil before installing oil separator,the oil should be same as the oil in the compressor crankcase.In the actual piping system,the excessive loads or vibration at the inlet and outlet should be prevented.Oil storage separator must be fixed in the mounting pin connections. Design features:1,Extra length multiayer filter mesh desgin will buffer the mixed gaseous refrigerant greatly.2,The installation of clapboard and spacer palte devide the space into three rooms,improving the efficiency of oil separating greatly.3,In practical application,the vibration of unit might affect ball float installation stability,so the clapboard and spacer plate could reduce the vibration og it.4,Reasonable stainless steel ball float installation desgin remove the crash of ball float and oil return pipe which reduced the noise.5,The installation of magner on the bottom absorb the remaining iron dust in the system helpfully. 
  • Liquid Accumulator
    Liquid Accumulator
    XMK-204 1/2 ODF Liquid Accumulator Refrigeration Parts
    XMK-204 Liquid Accumulator Refrigeration PartsHas stronger construction. It maximize prevents the refrigerant lost.The liquid accumulator separator is designed with internal bend pipes to prevent from internal splashing and help the aggregation of the oil at the bottom of the separator.The separator shall be installed as nearer to the compressor as possible.ModelConnector sizeXMK-2041/2 ODFXMK-2055/8 ODFXMK-2063/4 ODFXMK-2077/8 ODFXMK-208/2111-1/8 ODFXMK-209/2131-3/8 ODFXMK-210/2151-5/8 ODFXMK-2212-1/8 ODFFeatures:1. “U” tube design for maximum flow of refrigerant and minimum oil entrapment;2. Saving refrigerant;3. Metering Orifice matched to system capacity assures optimum liquid refrigerant and oil flow back to compressor.4. Exterior corrosion resistant static electrical painting process protecting the shell from the rust.5. Maximum working pressure: 3.0 Mpa.
  • Liquid Accumulator Part
    Liquid Accumulator Part
    XMK-205 5/8 ODF Liquid Accumulator HVAC Spare Part
    XMK-205 Liquid Accumulator Refrigeration Parts For Condensing Unit     Has stronger construction. It maximize prevents the refrigerant lost.   The liquid accumulator separator is designed with internal bend pipes to prevent from internal splashing and help the aggregation of the oil at the bottom of the separator.   The separator shall be installed as nearer to the compressor as possible.     Model Connector size XMK-204 1/2 ODF XMK-205 5/8 ODF XMK-206 3/4 ODF XMK-207 7/8 ODF XMK-208/211 1-1/8 ODF XMK-209/213 1-3/8 ODF XMK-210/215 1-5/8 ODF XMK-221 2-1/8 ODF   Features:   1. “U” tube design for maximum flow of refrigerant and minimum oil entrapment;   2. Saving refrigerant;   3. Metering Orifice matched to system capacity assures optimum liquid refrigerant and oil flow back to compressor.   4. Exterior corrosion resistant static electrical painting process protecting the shell from the rust.   5. Maximum working pressure: 3.0 Mpa.  
  • Oil Separator
    Oil Separator
    XMK-133 3/8 vertical Liquid Receiver Refrigeration
    XMK-133 3/8 vertical Liquid Receiver Refrigeration The liquid receiver acts as a stock of liquid refrigerant for the evaporators, located after the condenser in a refrigeration system.The selection of receiver size should be based on refrigerant charge in the system, and it also should be sized to hold the full system charge during service work, the capacity of each liquid receiver listed on Technical data sheet below.ModelConnector sizeXMK-1333/8XMK-2333/8XMK-3333/8XMK-4441/2XMK-6441/2XMK-8441/2XMK-10555/8XMK-12555/8XMK-14555/8Production Introduction:1.Designed for refrigerant storage in system’s normal operation or maintaining.2.System adjustment is allowed to suit with different condition or loading.3.Compatible with HFC, CFC, CFC and associated oils and additives4. Assemble a high quality rotator valve or safety valve.

A total of 1 pages

Categories

click here to leave a message

Leave A Message
If you are interested in our products and want to know more details,please leave a message here,we will reply you as soon as we can.

Home

Products

about

contact